In summary,
the isolation chamber is not designed to take into account
convective mass transfer caused by air movement. The aerodynamics
of the isolation chamber do not guarantee the repeatability
and reproducibility of the emission rates measured. The isolation
chamber should not be used to determine the emission rates
from an area surface for the use of dispersion model. The
portable wind tunnel system simulates wind movement in the
atmosphere and is considered to be a more appropriate sampling
technique in the determination of odour and VOC emissions
from an area surface.
REFERENCE
Gholson,
A. R., Albritton, J. R. Jayanty, R. K. M., Knoll, J. E. and
Midgett, M. R. (1991). Evaluation of an enclosure method for
measuring emissions of volatile organic compounds from quiescent
liquid surfaces. Envirn. Sci. Technol., 25:3, 519-524.
Gholson,
A. R. Albritton, J. R. Jayanty, R. K. M. 1989, Evaluation
of the flux chamber method for measuring volatile organic
emissions from surface impoundments, EPA/600/3-89/008, U.S.
Environmental Protection Agency, Research Triangle Park, NC.
PB89-148589.
Reinhart,
D. R., Copper, D. C., Walker, B. L. (1992). Flux chamber design
and operation for the measurement of municipal solid waste
landfill gas emission rates. J. Air Waste Manage. Assoc.,
42, 1067-1070.
Hwang,
S.T., (1985). "Model prediction of volatile emissions: A comparison
of several models for predicting emissions for hazardous waste
treatment facilities" Environmental Progress, 4:2, 141-144.