Pre-dilution technique for hot, wet and high strength
odour is recommended to maintain sample integrity. Pre-dilution
is used not only to prevent sample losses from hot and wet stack
sources but also to prevent contamination of the olfactometer
by highly odorous samples. The latter can extend the working dilution
range of the olfactometer.
Stack conditions such as pressure, temperature and
moisture level can affect the dilution ratios which are normally
determined under the normal conditions. For example, the high
stack pressure can increase the stack gas to be collected or the
hight temperature stack has less mass under normal temperature.
Despite the use of in-situ tracer gas calibration, the performance
of the system is largely dependent on the stack conditions and
calibration procedures. In fact, the dilution ratios from most
predilution stack samplers are assumed and is not measured in
the field condition.
DynaSampler offers an unique feature to allow the
dilution ratio to be determined during the sampling under the
field conditions. The efficiency of the predilution is continousely
monitored using built-in temperature and humidity sensors and
displayed on a pockPC via a wireless connection. This means that
no calibration required for the DynaSampler except for the calibration
of mass flow meter. The measured dilution ratio takes into
account the stack conditions (pressure, temperature and humidity).

DynaSampler predilution probe
The DynaSampeelr is light and portable. The operation
of the DynaSampler is simple and quick. The wireless connection
enables the process to be monitored and datalogged on a pockPC.
The cleaning of the Dynasampler is very efficient in the field
and can also be carried out through the washing in the laboroatry.